Castle Datalogging Sound Level Meter, 35dB to 140dB, 20kHz max

RS tilauskoodi: 909-1884Tuotemerkki: CastleValmistajan osanumero.: 01GA216B
brand-logo
Näytä kaikki Sound Level Meters tuotteet

Tekninen dokumentti

Tekniset tiedot

Merkki

Castle

Maximum Sound Level

140dB

Minimum Sound Level

35dB

Resolution

0.1 dB

DOSE Measurement

Yes

Weighting

A, C

Display Type

LCD

Battery Type

Alkaline, PP3

Fast/Slow Time Averaging

Both

Data Logging

Yes

Maximum Frequency

20kHz

Minimum Frequency

1 Hz

Alkuperämaa

United Kingdom

Tuotetiedot

Castle GA216B Sonus Class 2 Sound Pressure Level Meter (non data logging version)

Castle GA216B is designed for general survey health & safety and engineering applications by industrial safety officers, occupational nurses, fire alarm installation & test engineers and industrial engineers. It gives clear results which meet the requirements of international standards. GA216B is a Sonus range entry-level Type 2 sound meter fully compliant with IEC 61672-1:2002. The difference between Type 1 and Type 2 is in the tolerance, for example: at reference frequency 1kHz, tolerance is ±1.1dB (Type 1) and ±1.4dB (Type 2); at 20Hz, tolerance is ±2.5dB (Class 1) and ±3.5dB (Class 2). Compliance with IEC 61672-1:2002 Class 2 and IEC 60651:1979 Type 2 is necessary for carrying out most noise assessment tasks in industry.

Standards

IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

€ 558,09

kpl (ilman ALV)

€ 692,03

kpl (Sis ALV:n)

Castle Datalogging Sound Level Meter, 35dB to 140dB, 20kHz max

€ 558,09

kpl (ilman ALV)

€ 692,03

kpl (Sis ALV:n)

Castle Datalogging Sound Level Meter, 35dB to 140dB, 20kHz max
Varastotiedot eivät ole tilapäisesti saatavilla.

Tekninen dokumentti

Tekniset tiedot

Merkki

Castle

Maximum Sound Level

140dB

Minimum Sound Level

35dB

Resolution

0.1 dB

DOSE Measurement

Yes

Weighting

A, C

Display Type

LCD

Battery Type

Alkaline, PP3

Fast/Slow Time Averaging

Both

Data Logging

Yes

Maximum Frequency

20kHz

Minimum Frequency

1 Hz

Alkuperämaa

United Kingdom

Tuotetiedot

Castle GA216B Sonus Class 2 Sound Pressure Level Meter (non data logging version)

Castle GA216B is designed for general survey health & safety and engineering applications by industrial safety officers, occupational nurses, fire alarm installation & test engineers and industrial engineers. It gives clear results which meet the requirements of international standards. GA216B is a Sonus range entry-level Type 2 sound meter fully compliant with IEC 61672-1:2002. The difference between Type 1 and Type 2 is in the tolerance, for example: at reference frequency 1kHz, tolerance is ±1.1dB (Type 1) and ±1.4dB (Type 2); at 20Hz, tolerance is ±2.5dB (Class 1) and ±3.5dB (Class 2). Compliance with IEC 61672-1:2002 Class 2 and IEC 60651:1979 Type 2 is necessary for carrying out most noise assessment tasks in industry.

Standards

IEC 61672-1:2002 Class 2, IEC 60651: 1979 Type 2