Chauvin Arnoux CA 1631 Current & Voltage Calibrator, Max Voltage 20V dc, Max Current 24mA, RS Calibration

RS tilauskoodi: 810-6409Tuotemerkki: Chauvin ArnouxValmistajan osanumero.: P01654402
brand-logo

Tekninen dokumentti

Tekniset tiedot

Calibrated

RSCAL

Absolute Maximum Voltage Measurement

20V dc

Absolute Maximum Current Measurement

24mA

Best Accuracy

±0.015 %

Power Source

Battery, Mains

Battery Type

AAA

Dimensions

205 x 98 x 46mm

Weight

472g

Length

205mm

Maximum Operating Temperature

+55°C

Maximum Source Current

24mA

Minimum Operating Temperature

-10°C

Minimum Source Current

0mA

Model Number p

CA 1631

Maximum Source Voltage

0 mA, 20 V

Minimum Source Voltage

0V

Alkuperämaa

China

Tuotetiedot

Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631

These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

€ 1 105,00

kpl (ilman ALV)

€ 1 370,20

kpl (Sis ALV:n)

Chauvin Arnoux CA 1631 Current & Voltage Calibrator, Max Voltage 20V dc, Max Current 24mA, RS Calibration

€ 1 105,00

kpl (ilman ALV)

€ 1 370,20

kpl (Sis ALV:n)

Chauvin Arnoux CA 1631 Current & Voltage Calibrator, Max Voltage 20V dc, Max Current 24mA, RS Calibration
Varastotiedot eivät ole tilapäisesti saatavilla.

Tekninen dokumentti

Tekniset tiedot

Calibrated

RSCAL

Absolute Maximum Voltage Measurement

20V dc

Absolute Maximum Current Measurement

24mA

Best Accuracy

±0.015 %

Power Source

Battery, Mains

Battery Type

AAA

Dimensions

205 x 98 x 46mm

Weight

472g

Length

205mm

Maximum Operating Temperature

+55°C

Maximum Source Current

24mA

Minimum Operating Temperature

-10°C

Minimum Source Current

0mA

Model Number p

CA 1631

Maximum Source Voltage

0 mA, 20 V

Minimum Source Voltage

0V

Alkuperämaa

China

Tuotetiedot

Chauvin Arnoux Calibrators CA1621, CA1623 & CA1631

These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation and measurement. They simulate a signal or generate a quantity with precisely-defined values, for applying upstream of the measurement chain, and measure the signal. The CA1621, CA1623 & CA1631 calibrators are designed to accurately measure, generate or simulate all the low-level signals encountered in industry. Applications include maintenance operations, commissioning, verification, on-line calibration and adjustment and testing of measurement lines.