Signal Conditioning

Näet nyt 1 - 20 kaikkiaan 151 tuloksesta
Näytä:
Tuloksia per sivu
20
  • 20
  • 50
  • 100
Hinta
(Näytetty hinta ei sisällä alv:a)
Osan tiedot Merkki Input Type Uutuudet Output Type Signal Conditioner Type Input Range Output Range Supply Voltage Mounting Type Sensor Compatibility Minimum Operating Temperature Maximum Operating Temperature Series Special Features Standards Met Operating Temperature Range Module Type Termination Hazardous Area Certification Number of Channels
Phoenix Contact Amplifier Power Supply Repeater, 0 → 20 mA Input, 0 → 20 mA Output Phoenix Contact Current - Current Amplifier 0 → 20 mA 0 → 20 mA 24 V dc DIN Rail - -20°C +60°C - - - -20 → +60 °C - - - -
Phoenix Contact Power Bus Connector, 24 V ac Input, 24 V dc Output Phoenix Contact - - Analogue - 24 V ac 24 V dc 24 V dc DIN Rail - - - - - - - - - - -
Phoenix Contact Isolation Configurable Transducer, 1 mA Input, 0 → 10 V, 0 → 20 mA Output Phoenix Contact Current - Current, Voltage Isolation 1 mA 0 → 10 V, 0 → 20 mA 24 V dc DIN Rail RTD -20°C +65°C - - - -20 → +65 °C - - - -
Phoenix Contact Signal Duplicator Signal Conditioner, ATEX, 0 → 12 V, 0 → 24 mA Input Phoenix Contact Current, Voltage Current, Voltage Signal Duplicator 0 → 12 V, 0 → 24 mA 0 → 10.5 V, 0 → 21 mA 24 V dc DIN Rail - -40°C +70°C - Supports NFC Communication cUL, cULus, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-6-4, IEC 61010-1, UL -40 → +70 °C - Screw ATEX 1
Phoenix Contact Fibre Optic Converter, , 60 V ac/dc Output Phoenix Contact - - Voltage - - 60 V ac/dc 24 V dc DIN Rail - -20°C +60°C - - - -20 → +60 °C - - - -
Phoenix Contact Isolation Configurable Isolator, ATEX, Phoenix Contact - - Current, Voltage Isolation 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 4 → 20 mA 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 4 → 20 mA 24 V dc DIN Rail Potentiometer -20°C +65°C - - - -20 → +65 °C - - ATEX -
Phoenix Contact Isolation Galvanic Isolator, Phoenix Contact Current, Voltage - Current Isolation 0 → 40 mA (Configurable), -1000 mV → 30 V (Configurable) 4 → 20 mA 8 → 30 V dc DIN Rail - -25°C +70°C - - - -25 → +70 °C - - - -
Phoenix Contact Isolation Isolating Amplifier, Phoenix Contact Current, Voltage - Current, Voltage Isolation 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 4 → 20 mA 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 4 → 20 mA 24 V dc DIN Rail - -20°C +65°C - - - -20 → +65 °C - - - -
Phoenix Contact Isolation Isolating Amplifier, 0 → 10 V, -10 → 10 V Input Phoenix Contact Voltage - Voltage Isolation 0 → 10 V, -10 → 10 V 0 → 10 V, -10 → 10 V 24 V dc DIN Rail - -20°C +65°C - - - -20 → +65 °C - - - -
Phoenix Contact Signal Converter, 100 → 100000 Ω Input, 0 → 10 V, 0 → 20 mA Output Phoenix Contact - - Analogue - 100 → 100000 Ω 0 → 10 V, 0 → 20 mA 24 V dc DIN Rail - -20°C +65°C - - - -20 → +65 °C - - - -
Phoenix Contact Isolation Isolation Amplifier, 0 → 10 V Input, 0 → 10 V Output Phoenix Contact Voltage - Voltage Isolation 0 → 10 V 0 → 10 V 18 → 30 V dc DIN Rail - -20°C +65°C - - - -20 → +65 °C - - - -
Phoenix Contact Isolation Ethernet Network Islolator, 0 → 100 Mbit/s Input, 0 → 100 Mbit/s Output Phoenix Contact Frequency - Frequency Isolation 0 → 100 Mbit/s 0 → 100 Mbit/s - Side - -25°C +85°C - - - -25 → +85 °C - - - -
Phoenix Contact Isolation Galvanic Isolator, 9.6 → 30 V dc Input, 10 V dc, 2.5 V dc, 5 V dc, 7.5 V dc Output Phoenix Contact Voltage - Voltage Isolation 9.6 → 30 V dc 10 V dc, 2.5 V dc, 5 V dc, 7.5 V dc 9.6 → 30 V dc DIN Rail - -20°C +65°C - - - -20 → +65 °C - - - -
Phoenix Contact Isolation Repeater, Phoenix Contact - - - Isolation - - 24 V ac/dc DIN Rail - 0°C +55°C - - - 0 → +55 °C - - - -
Phoenix Contact Voltage to Voltage Amplifier, -1 V → 3 V, -800 mV → 800 mV Input Phoenix Contact Analogue, Voltage - Current, Voltage Voltage to Voltage -1 V → 3 V, -800 mV → 800 mV 0 V → 10 V, 0 mA → 20 mA 19.2 → 30 V dc DIN Rail Amplifier -20°C +65°C - - - -20 → +65 °C - - - -
Phoenix Contact Isolation Amplifier Signal Conditioner, 0 → 10 V Input, 0 → 20 mA Output Phoenix Contact Voltage - Current Isolation Amplifier 0 → 10 V 0 → 20 mA 9.6 → 30 V dc DIN Rail Transducer -40°C +70°C - - - -40 → +70 °C - - - -
Phoenix Contact Isolation Passive loop Isolator, 0 → 20 mA Input, 0 → 20 mA Output Phoenix Contact Current - Analogue Isolation 0 → 20 mA 0 → 20 mA 18 V DIN Rail Potentiometer -20°C +65°C - - - -20 → +65 °C - - - -
Phoenix Contact Frequency to Current, Frequency to Voltage Configurable Frequency Converter, Phoenix Contact Frequency - Current, Voltage Frequency to Current, Frequency to Voltage 0.002 Hz → 20 kHz 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 10 → 0 V, 20 → 0 mA, 20 → 4 mA, 4 → 20 mA 9.6 → 30 V dc DIN Rail NAMUR Sensor -20°C +65°C - - - -20 → +65 °C - - - -
Phoenix Contact Loop-Powered Isolator Signal Conditioner, ATEX, 0 → 20 mA, 4 → 20 mA Input Phoenix Contact Current Current Loop-Powered Isolator 0 → 20 mA, 4 → 20 mA 0 → 20 mA, 4 → 20 mA 9.6 → 30 V dc DIN Rail - -40°C +70°C - Supports NFC Communication cUL, cULus, EN 61000-6-4, IEC 61010-1, UL -40 → +70 °C - Push-In ATEX 1
Phoenix Contact Signal Converter, 0 → 10 V, 0 → 20 mA Input, 50 Hz Output Phoenix Contact - - Frequency - 0 → 10 V, 0 → 20 mA 50 Hz 20 → 30 V dc DIN Rail - -20°C +65°C - - - -20 → +65 °C - - - -
Tarkista varastotilanteemme
Anna haluamasi määrä ja klikkaa 'Tarkista'. Varastosaldo päivitettiin
.
RS-tuotenumero:
Etsin 
Vertaa koko listaa
Voit vertailla korkeintaan 8 tuotetta kerraallaan

Tarkastele tai poista tuotteita Vertailusivulla
Näet nyt 1 - 20 kaikkiaan 151 tuloksesta