Burkert Solenoid Valve 424103, 3 port(s) , NC, 24 V dc, 1/8in

RS tilauskoodi: 468-289Tuotemerkki: BurkertValmistajan osanumero.: 424103
brand-logo
Näytä kaikki Solenoid Valves tuotteet

Tekninen dokumentti

Tekniset tiedot

Merkki

Burkert

Supply Voltage

24 V dc

Number of Ports

3

Connection Size

1/8in

Connection

1/4 in G Female

Operation

Direct

Default Valve Position

NC

Suitable Applications

Compressed Air, Liquid, Neutral Gas

Type

3/2

Orifice Diameter

2mm

Series

6014P

Body Material

Brass

Maximum Working Pressure

10 bar

Operating Temperature Range

-10 → +55 °C

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

+55°C

Connection Gender

Female

Thread Standard or Connection Type

G

Maximum Opening Time

18ms

Maximum Closing Time

22ms

Flow Factor Kv

0.11m³/h

Alkuperämaa

Germany

Tuotetiedot

6014 General Purpose Solenoid Valve

Brass bodied, normally closed solenoid valves.

3 Way Inert Gases and Fluid Valves

Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and this is described on the right hand side of the diagram, see the typical schematic diagram below.,The 3//2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2//2-way valves as two-way.,The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications will indicate the appropriate connections and pressure capabilities should an alternative circuit function be required.

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

€ 187,00

kpl (ilman ALV)

€ 234,68

kpl (Sis ALV:n)

Burkert Solenoid Valve 424103, 3 port(s) , NC, 24 V dc, 1/8in

€ 187,00

kpl (ilman ALV)

€ 234,68

kpl (Sis ALV:n)

Burkert Solenoid Valve 424103, 3 port(s) , NC, 24 V dc, 1/8in
Varastotiedot eivät ole tilapäisesti saatavilla.

Osta irtotavarana

MääräYksikköhinta
1 - 4€ 187,00
5+€ 182,00

Tekninen dokumentti

Tekniset tiedot

Merkki

Burkert

Supply Voltage

24 V dc

Number of Ports

3

Connection Size

1/8in

Connection

1/4 in G Female

Operation

Direct

Default Valve Position

NC

Suitable Applications

Compressed Air, Liquid, Neutral Gas

Type

3/2

Orifice Diameter

2mm

Series

6014P

Body Material

Brass

Maximum Working Pressure

10 bar

Operating Temperature Range

-10 → +55 °C

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

+55°C

Connection Gender

Female

Thread Standard or Connection Type

G

Maximum Opening Time

18ms

Maximum Closing Time

22ms

Flow Factor Kv

0.11m³/h

Alkuperämaa

Germany

Tuotetiedot

6014 General Purpose Solenoid Valve

Brass bodied, normally closed solenoid valves.

3 Way Inert Gases and Fluid Valves

Compact solenoid valves suitable for most gas and fluid handling applications. Where practical, valves are shown with a schematic diagram showing the (circuit) function. The diagram is laid out so that the left hand side of the diagram describes the valves operation when the coil is energised. When the coil is de-energised, the spring (or servo-assist) return controls the valve and this is described on the right hand side of the diagram, see the typical schematic diagram below.,The 3//2-way designation indicates a valve with three ports and two modes of operation. It is normal practice to refer to 2//2-way valves as two-way.,The port designations A, B, P, P1, P2 and R are used on the schematic diagrams and are marked on the valve bodies. Valve bodies are marked for a specific circuit function but can often be used for other functions. Reference to the schematic diagrams and technical specifications will indicate the appropriate connections and pressure capabilities should an alternative circuit function be required.