Turck 1 Channel Galvanic Barrier, HART Isolating Transducer, Current Input, Current Output, ATEX, IECEx

RS tilauskoodi: 808-6526Tuotemerkki: TurckValmistajan osanumero.: IM35-11EX-HI/24VDC
brand-logo

Tekninen dokumentti

Tekniset tiedot

Merkki

Turck

Number of Channels

1

Module Type

HART Isolating Transducer

Barrier Type

Galvanic Barrier

Output Signal Type

Current

Maximum Voltage

250V

Interface

HART

Hazardous Area Certification

ATEX, IECEx

Input Signal Type

Current

Supply Voltage

24V dc

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

+70°C

Safety Voltage Maximum

250 V

Operating Temperature Range

-25 → +70°C

Alkuperämaa

Germany

Tuotetiedot

Isolating Transducer

Professional range of galvanically isolated Isolating transducers for the transmission of a unattenuated output signal to the non-Ex area. This series is environmentally versatile and comes with a variety of approvals, meaning the IM signal conditioning series can be installed in a comprehensive range of applications

Standards

ATEX, IECEx, FM, UL, GOST

Turck Banner DIN Rail Mounting

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

€ 370,00

kpl (ilman ALV)

€ 464,35

kpl (Sis ALV:n)

Turck 1 Channel Galvanic Barrier, HART Isolating Transducer, Current Input, Current Output, ATEX, IECEx

€ 370,00

kpl (ilman ALV)

€ 464,35

kpl (Sis ALV:n)

Turck 1 Channel Galvanic Barrier, HART Isolating Transducer, Current Input, Current Output, ATEX, IECEx
Varastotiedot eivät ole tilapäisesti saatavilla.

Tekninen dokumentti

Tekniset tiedot

Merkki

Turck

Number of Channels

1

Module Type

HART Isolating Transducer

Barrier Type

Galvanic Barrier

Output Signal Type

Current

Maximum Voltage

250V

Interface

HART

Hazardous Area Certification

ATEX, IECEx

Input Signal Type

Current

Supply Voltage

24V dc

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

+70°C

Safety Voltage Maximum

250 V

Operating Temperature Range

-25 → +70°C

Alkuperämaa

Germany

Tuotetiedot

Isolating Transducer

Professional range of galvanically isolated Isolating transducers for the transmission of a unattenuated output signal to the non-Ex area. This series is environmentally versatile and comes with a variety of approvals, meaning the IM signal conditioning series can be installed in a comprehensive range of applications

Standards

ATEX, IECEx, FM, UL, GOST

Turck Banner DIN Rail Mounting