Tekninen dokumentti
Tekniset tiedot
Merkki
RS ProCross Sectional Area
1.5 mm²
Number of Cores
3
Sheath Colour
Grey
Length
100m
Cable Type
NYM-J
CPR Certification
Eca
Outer Diameter
10.5mm
Sheath Material
PVC
Voltage Rating
500 V
Conductor Strand Type
Solid
Size of Strands
1.365 mm
Maximum Operating Temperature
+70°C
Conductor Resistance
12.1 Ω/km
Insulation material
PVC
Fire Behaviour
Flame Retardant
Minimum Operating Temperature
-5°C
Standards Met
HD 21.4 S2, IEC 60228 Class1, IEC 60332-1
Alkuperämaa
Turkey
Tuotetiedot
RS PRO NYM-J Mains Installation Cable
Introducing the RS PRO NYM-J mains installation cable. This electrical cable features a PVC outer sheath and a nominal voltage rating of 300/500 V used for electrical wiring installations inside buildings. The high-quality mains power cable is suitable for use in dry, damp or wet areas and can be installed in, on or under plaster, brickwork or concrete, however, it is not recommended that this cable is laid into compacted concrete. It can also only be used in outdoor applications if the electric cable is not exposed to direct sunlight as it is not UV tolerant.
€ 254,00
€ 254,00 1 kela 100 metriä (ilman ALV)
€ 318,77
€ 318,77 1 kela 100 metriä (Sis ALV:n)
1
€ 254,00
€ 254,00 1 kela 100 metriä (ilman ALV)
€ 318,77
€ 318,77 1 kela 100 metriä (Sis ALV:n)
1
Varastotiedot eivät ole tilapäisesti saatavilla.
Tarkista myöhemmin uudelleen.
Tekninen dokumentti
Tekniset tiedot
Merkki
RS ProCross Sectional Area
1.5 mm²
Number of Cores
3
Sheath Colour
Grey
Length
100m
Cable Type
NYM-J
CPR Certification
Eca
Outer Diameter
10.5mm
Sheath Material
PVC
Voltage Rating
500 V
Conductor Strand Type
Solid
Size of Strands
1.365 mm
Maximum Operating Temperature
+70°C
Conductor Resistance
12.1 Ω/km
Insulation material
PVC
Fire Behaviour
Flame Retardant
Minimum Operating Temperature
-5°C
Standards Met
HD 21.4 S2, IEC 60228 Class1, IEC 60332-1
Alkuperämaa
Turkey
Tuotetiedot
RS PRO NYM-J Mains Installation Cable
Introducing the RS PRO NYM-J mains installation cable. This electrical cable features a PVC outer sheath and a nominal voltage rating of 300/500 V used for electrical wiring installations inside buildings. The high-quality mains power cable is suitable for use in dry, damp or wet areas and can be installed in, on or under plaster, brickwork or concrete, however, it is not recommended that this cable is laid into compacted concrete. It can also only be used in outdoor applications if the electric cable is not exposed to direct sunlight as it is not UV tolerant.