Tekninen dokumentti
Tekniset tiedot
Merkki
Aim-TTiMultimeter Type
Bench
Display Type
Digital
Model Number p
1908P
Calibrated
RSCAL
Functions Measured
AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature
Absolute Maximum DC Current Measurement
10A dc
Absolute Maximum AC Current Measurement
10A ac
Absolute Maximum Resistance Measurement
1kΩ
Absolute Maximum AC Voltage Measurement
1000V ac
Absolute Maximum DC Voltage Measurement
1000V dc
Absolute Maximum Temperature Measurement
+400°C
Absolute Maximum Capacitance Measurement
100µF
Maximum Frequency
100kHz
AC Current Measurement Resolution
100nA ac
DC Current Measurement Resolution
100nA dc
Resistance Measurement Resolution
1mΩ
DC Voltage Measurement Resolution
1µV dc
AC Voltage Measurement Resolution
1µV ac
Safety Category Level
CAT II
Temperature Measurement Resolution
0.1°C
Capacitance Measurement Resolution
10pF
Weight
2kg
Best DC Current Accuracy
0.05 %
Safety Category Voltage
600V
Battery Type
Rechargeable NiMH
Width
235mm
Length
260mm
Best AC Current Accuracy
0.35 %
Dimensions
260 x 235 x 88mm
Best DC Voltage Accuracy
0.02 %
Best Resistance Measurement Accuracy
0.05 %
Maximum Operating Temperature
+40°C
Best Temperature Measurement Accuracy
0.05 %
Best AC Voltage Accuracy
0.3 %
Best Capacitance Measurement Accuracy
2 %
Minimum Operating Temperature
+5°C
Height
88mm
Alkuperämaa
United Kingdom
Tuotetiedot
Aim-TTI 1908P Series Dual Measurement Bench Multimeter
Aim-TTi 1908 Series is a dual measurement, dual display bench-top/portable multimeter. It features continuity and diode test, automatic or manual ranging, linear scaling with offset, dB measurements, limits comparison, percentage deviation (%), min-max storage, power measurement in watts or VA, automatic data logging and external triggering. The logger function can store up to 500 readings from the main display in non-volatile memory. The two displays can be used to display a measurement along with the selected range (e.g. 100 Vdc), a measurement in two different units (e.g. AC volts and dBm), the result of a calculated function (e.g. value and % deviation), two parameters of one signal (e.g. AC and DC volts) or two different signals (e.g. AC volts and DC current). Software 1908-PC Link provides remote control of main functions and logging function with graphical and tabular displays (logged data can be exported to a CSV file). Model 1908P can be remotely controlled via its RS232, USB or LAN interface. Model 1908 (non P) can only be controlled via USB.
For an optional GPIB module see stock number 144-5481.
Supplied with
IVI driver, LV/CVI driver, USB driver
Standards
EN61010-1, EN61010-2-030 & EN61010-2-033, EN61326-1 EMC
Varastotiedot eivät ole tilapäisesti saatavilla.
Tarkista myöhemmin uudelleen.
€ 980,00
kpl (ilman ALV)
€ 1 215,20
kpl (Sis ALV:n)
1
€ 980,00
kpl (ilman ALV)
€ 1 215,20
kpl (Sis ALV:n)
1
Tekninen dokumentti
Tekniset tiedot
Merkki
Aim-TTiMultimeter Type
Bench
Display Type
Digital
Model Number p
1908P
Calibrated
RSCAL
Functions Measured
AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature
Absolute Maximum DC Current Measurement
10A dc
Absolute Maximum AC Current Measurement
10A ac
Absolute Maximum Resistance Measurement
1kΩ
Absolute Maximum AC Voltage Measurement
1000V ac
Absolute Maximum DC Voltage Measurement
1000V dc
Absolute Maximum Temperature Measurement
+400°C
Absolute Maximum Capacitance Measurement
100µF
Maximum Frequency
100kHz
AC Current Measurement Resolution
100nA ac
DC Current Measurement Resolution
100nA dc
Resistance Measurement Resolution
1mΩ
DC Voltage Measurement Resolution
1µV dc
AC Voltage Measurement Resolution
1µV ac
Safety Category Level
CAT II
Temperature Measurement Resolution
0.1°C
Capacitance Measurement Resolution
10pF
Weight
2kg
Best DC Current Accuracy
0.05 %
Safety Category Voltage
600V
Battery Type
Rechargeable NiMH
Width
235mm
Length
260mm
Best AC Current Accuracy
0.35 %
Dimensions
260 x 235 x 88mm
Best DC Voltage Accuracy
0.02 %
Best Resistance Measurement Accuracy
0.05 %
Maximum Operating Temperature
+40°C
Best Temperature Measurement Accuracy
0.05 %
Best AC Voltage Accuracy
0.3 %
Best Capacitance Measurement Accuracy
2 %
Minimum Operating Temperature
+5°C
Height
88mm
Alkuperämaa
United Kingdom
Tuotetiedot
Aim-TTI 1908P Series Dual Measurement Bench Multimeter
Aim-TTi 1908 Series is a dual measurement, dual display bench-top/portable multimeter. It features continuity and diode test, automatic or manual ranging, linear scaling with offset, dB measurements, limits comparison, percentage deviation (%), min-max storage, power measurement in watts or VA, automatic data logging and external triggering. The logger function can store up to 500 readings from the main display in non-volatile memory. The two displays can be used to display a measurement along with the selected range (e.g. 100 Vdc), a measurement in two different units (e.g. AC volts and dBm), the result of a calculated function (e.g. value and % deviation), two parameters of one signal (e.g. AC and DC volts) or two different signals (e.g. AC volts and DC current). Software 1908-PC Link provides remote control of main functions and logging function with graphical and tabular displays (logged data can be exported to a CSV file). Model 1908P can be remotely controlled via its RS232, USB or LAN interface. Model 1908 (non P) can only be controlled via USB.
For an optional GPIB module see stock number 144-5481.
Supplied with
IVI driver, LV/CVI driver, USB driver
Standards
EN61010-1, EN61010-2-030 & EN61010-2-033, EN61326-1 EMC