Comark C9006/IS Handheld Digital Thermometer, J, K, N, R, S, T Probe, 1 Input(s), +1767°C Max, ±0.2 °C Accuracy - RS

RS Stock No.: 451-789Brand: ComarkManufacturers Part No.: C9006IS
brand-logo
View all in Digital Thermometers

Technical Document

Specifications

Brand

Comark

Absolute Maximum Temperature Measurement

+1767°C

Calibrated

RSCAL

Model Number

C9006/IS

Probe Type

J, K, N, R, S, T

Thermometer Type

Handheld

Best Accuracy

±0.2 °C

Number of Temperature Inputs

1

Resolution

0.1 °C

Data Storage

Yes

Length

150mm

Width

82mm

Height

31mm

Dimensions

150 x 82 x 31mm

Temperature Scale

Centigrade

Minimum/Maximum Recordings

Yes

Product details

C90061S

Approved for use in explosive atmospheres (group IIC gas types and T4 temperatures classification) in Zone 0 hazardous areas. Rated to IP67
Compatible with K, N, T, J, R & S thermocouples
Selectable °C, °F, °A (Kelvin), setting retained
Max/Min/Actual Temp. and Hold operating modes
0·1°C resolution with autoranging at 1000°C
Indication of low battery, overrange and open circuit
Selectable auto switch-off setting retained
Battery required MN1604 Alkaline battery example stock no (448-8511)
Instruction leaflet included
Dimensions H. 150 W. 82 (max) D. 31mm

Price on Asking

Comark C9006/IS Handheld Digital Thermometer, J, K, N, R, S, T Probe, 1 Input(s), +1767°C Max, ±0.2 °C Accuracy - RS

Price on Asking

Comark C9006/IS Handheld Digital Thermometer, J, K, N, R, S, T Probe, 1 Input(s), +1767°C Max, ±0.2 °C Accuracy - RS

Stock information temporarily unavailable.

Stock information temporarily unavailable.

Technical Document

Specifications

Brand

Comark

Absolute Maximum Temperature Measurement

+1767°C

Calibrated

RSCAL

Model Number

C9006/IS

Probe Type

J, K, N, R, S, T

Thermometer Type

Handheld

Best Accuracy

±0.2 °C

Number of Temperature Inputs

1

Resolution

0.1 °C

Data Storage

Yes

Length

150mm

Width

82mm

Height

31mm

Dimensions

150 x 82 x 31mm

Temperature Scale

Centigrade

Minimum/Maximum Recordings

Yes

Product details

C90061S

Approved for use in explosive atmospheres (group IIC gas types and T4 temperatures classification) in Zone 0 hazardous areas. Rated to IP67
Compatible with K, N, T, J, R & S thermocouples
Selectable °C, °F, °A (Kelvin), setting retained
Max/Min/Actual Temp. and Hold operating modes
0·1°C resolution with autoranging at 1000°C
Indication of low battery, overrange and open circuit
Selectable auto switch-off setting retained
Battery required MN1604 Alkaline battery example stock no (448-8511)
Instruction leaflet included