Electrotherm Digital Transducer

RS tilauskoodi: 913-0866Tuotemerkki: ElectrothermValmistajan osanumero.: LKM 282
brand-logo

Tekninen dokumentti

Tekniset tiedot

Termination Type

Screw

Alkuperämaa

Germany

Tuotetiedot

LKM 282 Digital Programmable Measuring Transducer

The LKM 282 series is a digital programmable galvanically isolated measuring transducer for thermocouples. The transducer is mounted on standard rails. The LKM 282 transducer was designed to be used in cars. The transducer has a high interference immunity plus a wide range of voltages even a supply voltage of 8V you can obtain a liner output signal of 10V. A slim 6mm design means this transducer takes little space on a standard rail and has optimum shock resistance.
An added benefit to all users is that this measuring transducer can be programmed for a variety of thermocouples all to DIN EN 60584-3.The sensors thermoelectric emfs are converted temperature linearly into the output signal which ranges from 0 to 10V. This is where temperature compensation takes place within the measuring transducer which is configured via a micro USB port.

Approvals

EN61326-1:2006
EN61326-2-3:2006

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

€ 211,70

€ 211,70 kpl (ilman ALV)

€ 265,68

€ 265,68 kpl (Sis ALV:n)

Electrotherm Digital Transducer

€ 211,70

€ 211,70 kpl (ilman ALV)

€ 265,68

€ 265,68 kpl (Sis ALV:n)

Electrotherm Digital Transducer
Varastotiedot eivät ole tilapäisesti saatavilla.

Osta irtotavarana

MääräYksikköhinta
1 - 4€ 211,70
5 - 9€ 205,36
10+€ 196,88

Tekninen dokumentti

Tekniset tiedot

Termination Type

Screw

Alkuperämaa

Germany

Tuotetiedot

LKM 282 Digital Programmable Measuring Transducer

The LKM 282 series is a digital programmable galvanically isolated measuring transducer for thermocouples. The transducer is mounted on standard rails. The LKM 282 transducer was designed to be used in cars. The transducer has a high interference immunity plus a wide range of voltages even a supply voltage of 8V you can obtain a liner output signal of 10V. A slim 6mm design means this transducer takes little space on a standard rail and has optimum shock resistance.
An added benefit to all users is that this measuring transducer can be programmed for a variety of thermocouples all to DIN EN 60584-3.The sensors thermoelectric emfs are converted temperature linearly into the output signal which ranges from 0 to 10V. This is where temperature compensation takes place within the measuring transducer which is configured via a micro USB port.

Approvals

EN61326-1:2006
EN61326-2-3:2006