Fulleon Symphoni Series Red Beacon, 18 → 30 V dc, Surface Mount, 100dB at 1 Metre

RS tilauskoodi: 180-575Tuotemerkki: FulleonValmistajan osanumero.: SYAV/RL/R
brand-logo
Näytä kaikki Äänimajakat tuotteet

Tekninen dokumentti

Tekniset tiedot

Merkki

Fulleon

Supply Voltage

18 → 30 V dc

Lens Colour

Red

Mounting Style

Surface Mount

Current Type

DC

Light Effect

Flashing

Sounder Type

Electronic

Decibels at 1 Metre

100dB

Series

Symphoni

Bulb Type

LED

Housing Colour

Red

Number Of Tones

5

Minimum Temperature

-25°C

Housing Material

ABS

Maximum Temperature

+55°C

Tuotetiedot

Symphoni AV

This combination of LED beacon and high output sounder provide an extremely efficient solution for system extensions and upgrades without adding undue loading to power supplies or sounder circuits

Warning

This product exceeds the requirements of En54-3 but is not designed to meet EN54-23. Where the Construction Product Directive or Regulation (CPD/CPR) is a country requirement, it cannot be used, legally, for the purpose of alerting room occupants to a Fire Alarm condition. For Countries where CPD/CPR does not apply, this note should be disregarded.

Standards

CPD

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

Hintaa ei saatavilla

Fulleon Symphoni Series Red Beacon, 18 → 30 V dc, Surface Mount, 100dB at 1 Metre

Hintaa ei saatavilla

Fulleon Symphoni Series Red Beacon, 18 → 30 V dc, Surface Mount, 100dB at 1 Metre
Varastotiedot eivät ole tilapäisesti saatavilla.

Tekninen dokumentti

Tekniset tiedot

Merkki

Fulleon

Supply Voltage

18 → 30 V dc

Lens Colour

Red

Mounting Style

Surface Mount

Current Type

DC

Light Effect

Flashing

Sounder Type

Electronic

Decibels at 1 Metre

100dB

Series

Symphoni

Bulb Type

LED

Housing Colour

Red

Number Of Tones

5

Minimum Temperature

-25°C

Housing Material

ABS

Maximum Temperature

+55°C

Tuotetiedot

Symphoni AV

This combination of LED beacon and high output sounder provide an extremely efficient solution for system extensions and upgrades without adding undue loading to power supplies or sounder circuits

Warning

This product exceeds the requirements of En54-3 but is not designed to meet EN54-23. Where the Construction Product Directive or Regulation (CPD/CPR) is a country requirement, it cannot be used, legally, for the purpose of alerting room occupants to a Fire Alarm condition. For Countries where CPD/CPR does not apply, this note should be disregarded.

Standards

CPD