Omron Dual-Channel Emergency Stop Safety Relay, 100 → 240V ac, 5 Safety Contacts

RS tilauskoodi: 757-9323Tuotemerkki: OmronValmistajan osanumero.: G9SA-501 AC100-240
brand-logo
Näytä kaikki Safety Relays tuotteet

Tekninen dokumentti

Tekniset tiedot

Merkki

Omron

Supply Voltage

100 → 240V ac

Number of Channels

2

Safety Contacts

5

Function

Emergency Stop

Auxiliary Contacts

1

Safety Category ISO 13849-1

4

Safety Category (ISO 13849-1)

4

PL ISO 13849-1

e

PL (ISO 13849-1)

e

Depth

111mm

Series

G9SA

Width

45mm

Performance Level

e

Length

94mm

Alkuperämaa

China

Tuotetiedot

G9SA, Safety Relays, Expandable

The G9SA family offers a line-up of compact and expandable safety relay units. Modules with safe OFF-delay timing are available as well as a two hand controller. Simple multiplication of safety contacts is possible by using the connection on the front.

Approvals

UL, CSA

Standards

EN954-1, EN60204-1, EN574 (-TH301), UL508, CSA C22.2 No. 14

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

€ 416,00

kpl (ilman ALV)

€ 515,84

kpl (Sis ALV:n)

Omron Dual-Channel Emergency Stop Safety Relay, 100 → 240V ac, 5 Safety Contacts

€ 416,00

kpl (ilman ALV)

€ 515,84

kpl (Sis ALV:n)

Omron Dual-Channel Emergency Stop Safety Relay, 100 → 240V ac, 5 Safety Contacts
Varastotiedot eivät ole tilapäisesti saatavilla.

Tekninen dokumentti

Tekniset tiedot

Merkki

Omron

Supply Voltage

100 → 240V ac

Number of Channels

2

Safety Contacts

5

Function

Emergency Stop

Auxiliary Contacts

1

Safety Category ISO 13849-1

4

Safety Category (ISO 13849-1)

4

PL ISO 13849-1

e

PL (ISO 13849-1)

e

Depth

111mm

Series

G9SA

Width

45mm

Performance Level

e

Length

94mm

Alkuperämaa

China

Tuotetiedot

G9SA, Safety Relays, Expandable

The G9SA family offers a line-up of compact and expandable safety relay units. Modules with safe OFF-delay timing are available as well as a two hand controller. Simple multiplication of safety contacts is possible by using the connection on the front.

Approvals

UL, CSA

Standards

EN954-1, EN60204-1, EN574 (-TH301), UL508, CSA C22.2 No. 14