Omron S8VK-X Switched Mode DIN Rail Power Supply, 100 → 240V ac ac Input, 12V dc dc Output, 4.5A Output, 60W

RS tilauskoodi: 174-5846Tuotemerkki: OmronValmistajan osanumero.: S8VK-X06012-EIP
brand-logo

Tekninen dokumentti

Tekniset tiedot

Merkki

Omron

Type

Switch Mode

Type

Switched Mode

Output Voltage

12V dc

Output Current

4.5A

AC or DC Input Voltage

ac, dc

AC or DC Input Voltage

ac

AC or DC Output Voltage

dc

Input Voltage

230V ac

Input Voltage

100 → 240V ac

Power Rating

60W

Electrical Phase

1

Number of Outputs

1

Height

90mm

Width

40mm

Depth

92mm

Series

S8VK-X

Output Voltage Adjustment Range

10.8 → 14V

Load Regulation

1.5%

Special Features

and more are Acquired on the Network and can be Managed all at Once, Output Current, Output Voltage, Power Boost Function at 150%, Replacement Time, Status Can be Checked On-Site Using the Indication Monitor

Maximum Temperature

+70°C

Standards Met

CE, cULus, EAC, EN 61000-3-2, EN 61204-3, EN/IEC 60529, EN/IEC 61558-2-16, TUV, UL

MTBF

160000h

Mounting Type

DIN Rail Mount

Minimum Temperature

-40°C

Efficiency

86%

Ripple And Noise

120mV Pk-Pk

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

€ 196,00

kpl (ilman ALV)

€ 243,04

kpl (Sis ALV:n)

Omron S8VK-X Switched Mode DIN Rail Power Supply, 100 → 240V ac ac Input, 12V dc dc Output, 4.5A Output, 60W

€ 196,00

kpl (ilman ALV)

€ 243,04

kpl (Sis ALV:n)

Omron S8VK-X Switched Mode DIN Rail Power Supply, 100 → 240V ac ac Input, 12V dc dc Output, 4.5A Output, 60W
Varastotiedot eivät ole tilapäisesti saatavilla.

Tekninen dokumentti

Tekniset tiedot

Merkki

Omron

Type

Switch Mode

Type

Switched Mode

Output Voltage

12V dc

Output Current

4.5A

AC or DC Input Voltage

ac, dc

AC or DC Input Voltage

ac

AC or DC Output Voltage

dc

Input Voltage

230V ac

Input Voltage

100 → 240V ac

Power Rating

60W

Electrical Phase

1

Number of Outputs

1

Height

90mm

Width

40mm

Depth

92mm

Series

S8VK-X

Output Voltage Adjustment Range

10.8 → 14V

Load Regulation

1.5%

Special Features

and more are Acquired on the Network and can be Managed all at Once, Output Current, Output Voltage, Power Boost Function at 150%, Replacement Time, Status Can be Checked On-Site Using the Indication Monitor

Maximum Temperature

+70°C

Standards Met

CE, cULus, EAC, EN 61000-3-2, EN 61204-3, EN/IEC 60529, EN/IEC 61558-2-16, TUV, UL

MTBF

160000h

Mounting Type

DIN Rail Mount

Minimum Temperature

-40°C

Efficiency

86%

Ripple And Noise

120mV Pk-Pk