Pilz PSENme Series Solenoid Interlock Switch, Power to Unlock, 110V ac, Actuator Included

RS tilauskoodi: 744-8667Tuotemerkki: PilzValmistajan osanumero.: PSEN me1.2S/1AR
brand-logo

Tekninen dokumentti

Tekniset tiedot

Merkki

Pilz

Power to Lock / Unlock

Power to Unlock

Supply Voltage

110V ac

Series

PSENme

Actuator Included

Yes

Range

PSENmech

Actuator Type

Radius

Conduit Entry

M20

Housing Material

Plastic

IP Rating

IP67

Depth

51mm

Width

42.5mm

Length

184mm

Alkuperämaa

Germany

Tuotetiedot

PSENmech Safety Switch

The PSENmech mechanical safety switch is suitable for the safe monitoring of a movable guard. The safety switch is triggered if the guards are opened, and the hazardous machine movement is stopped via a Pilz evaluation device. The PSENmech safety switch prevents the safety gate from being opened unintentionally by using increased extraction force on the actuator. It complies with EN 1088 standard (protection against defeat) thanks to its mechanically coded actuator.

Approvals

EC, BG, CCC, cCSAus

Standards

VDE 0660 T100, EN 60947-1, VDE 0660 T200, EN 60947-5-1, IEC 60947-5-1 GS-ET-19

Saatat olla kiinnostunut

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

Hintaa ei saatavilla

Pilz PSENme Series Solenoid Interlock Switch, Power to Unlock, 110V ac, Actuator Included

Hintaa ei saatavilla

Pilz PSENme Series Solenoid Interlock Switch, Power to Unlock, 110V ac, Actuator Included
Varastotiedot eivät ole tilapäisesti saatavilla.
Saatat olla kiinnostunut

Tekninen dokumentti

Tekniset tiedot

Merkki

Pilz

Power to Lock / Unlock

Power to Unlock

Supply Voltage

110V ac

Series

PSENme

Actuator Included

Yes

Range

PSENmech

Actuator Type

Radius

Conduit Entry

M20

Housing Material

Plastic

IP Rating

IP67

Depth

51mm

Width

42.5mm

Length

184mm

Alkuperämaa

Germany

Tuotetiedot

PSENmech Safety Switch

The PSENmech mechanical safety switch is suitable for the safe monitoring of a movable guard. The safety switch is triggered if the guards are opened, and the hazardous machine movement is stopped via a Pilz evaluation device. The PSENmech safety switch prevents the safety gate from being opened unintentionally by using increased extraction force on the actuator. It complies with EN 1088 standard (protection against defeat) thanks to its mechanically coded actuator.

Approvals

EC, BG, CCC, cCSAus

Standards

VDE 0660 T100, EN 60947-1, VDE 0660 T200, EN 60947-5-1, IEC 60947-5-1 GS-ET-19

Saatat olla kiinnostunut