Technical Document
Specifications
Brand
P.M.AProduct Type
PID Temperature Controller
Output Type
Optocoupler, Logic, Relay, Analogue (0/4 to 20 mA), Analogue Voltage (0/2 to 10 V)
Number of Outputs
4
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
65°C
Control Type
2 Point Control (On/Off), 3 Point Stepping Control, Continuous Controller with Internal Positioner, PID, PID Heating and Cooling, Delta/Star/Off+2 Point Controller (Load Switching)
Maximum Supply Voltage
260V ac
Digital Comms
RS422/RS485/Modbus RTU, PROFIBUS-DP
Diagnostics
Error Signals and Warnings Display, Maintenance Manager and Error List, Dac Actuator Diagnostics, Monitoring Of Heating Current and Output Circuit
Length
118mm
Standards/Approvals
EN 61010-1, DIN 4754, cULus (File: E 208286), EN 14597, EN 61326-1, DIN 4751, DIN 3440, DIN 4752, DIN 4755
Width
48mm
IP Rating
IP00, IP20, IP65
Series
KS
Mount Type
Panel
Input Type
Current, Voltage, Thermocouple
Panel Depth
118mm
Country of Origin
United Kingdom
Product details
PMA KS 90-1 Temperature Controller
The KS 90-1 process controller is suitable for universal, precise, and cost-effective control. The instrument provides simple 2-point (on/off) control, continuous PID control, or 3-point stepping control.
The process value signal is connected via a universal input. A supplementary analog input can be used for heating current measurement, as an external set-point inputter for position feedback measurement of motorised stepping controllers.
The optional 3rd input is a universal input that can be used for several functions, e.g. temperature dependent setpoint correction or differential control. The standard KS 90-1 is suitable for oxygen control using heated and unheated O2 sensors.
The KS 90-1 is particularly suited to the following applications: Furnaces and ovens, Burners and boilers, Plastics processing & Driers.
• BluePort®
• Front interface and BlueControl software
• Maintenance manager and error list
• Two universal inputs
• Day & Night display shows plain text and bargraphs
• Manual gain scheduling
• Self-Tuning to the setpoint without oscillation
• Valve controller with position feedback and DAC monitoring
• 3-point controller for water, fan and oil cooling
• Type tested to EN 14597 (replaces DIN 3440) and cULus
• High-impedance mV input for O2 sensors
PMA Temperature Controllers
Stock information temporarily unavailable.
€ 854.38
€ 854.38 Each (Exc. Vat)
€ 1,072.25
€ 1,072.25 Each (inc. VAT)
1
€ 854.38
€ 854.38 Each (Exc. Vat)
€ 1,072.25
€ 1,072.25 Each (inc. VAT)
Stock information temporarily unavailable.
1
Technical Document
Specifications
Brand
P.M.AProduct Type
PID Temperature Controller
Output Type
Optocoupler, Logic, Relay, Analogue (0/4 to 20 mA), Analogue Voltage (0/2 to 10 V)
Number of Outputs
4
Minimum Operating Temperature
-20°C
Maximum Operating Temperature
65°C
Control Type
2 Point Control (On/Off), 3 Point Stepping Control, Continuous Controller with Internal Positioner, PID, PID Heating and Cooling, Delta/Star/Off+2 Point Controller (Load Switching)
Maximum Supply Voltage
260V ac
Digital Comms
RS422/RS485/Modbus RTU, PROFIBUS-DP
Diagnostics
Error Signals and Warnings Display, Maintenance Manager and Error List, Dac Actuator Diagnostics, Monitoring Of Heating Current and Output Circuit
Length
118mm
Standards/Approvals
EN 61010-1, DIN 4754, cULus (File: E 208286), EN 14597, EN 61326-1, DIN 4751, DIN 3440, DIN 4752, DIN 4755
Width
48mm
IP Rating
IP00, IP20, IP65
Series
KS
Mount Type
Panel
Input Type
Current, Voltage, Thermocouple
Panel Depth
118mm
Country of Origin
United Kingdom
Product details
PMA KS 90-1 Temperature Controller
The KS 90-1 process controller is suitable for universal, precise, and cost-effective control. The instrument provides simple 2-point (on/off) control, continuous PID control, or 3-point stepping control.
The process value signal is connected via a universal input. A supplementary analog input can be used for heating current measurement, as an external set-point inputter for position feedback measurement of motorised stepping controllers.
The optional 3rd input is a universal input that can be used for several functions, e.g. temperature dependent setpoint correction or differential control. The standard KS 90-1 is suitable for oxygen control using heated and unheated O2 sensors.
The KS 90-1 is particularly suited to the following applications: Furnaces and ovens, Burners and boilers, Plastics processing & Driers.
• BluePort®
• Front interface and BlueControl software
• Maintenance manager and error list
• Two universal inputs
• Day & Night display shows plain text and bargraphs
• Manual gain scheduling
• Self-Tuning to the setpoint without oscillation
• Valve controller with position feedback and DAC monitoring
• 3-point controller for water, fan and oil cooling
• Type tested to EN 14597 (replaces DIN 3440) and cULus
• High-impedance mV input for O2 sensors