Sollatek Refrigeration control 16A Over Voltage and Under Voltage, 3680VA, Chassis

RS tilauskoodi: 848-4500Tuotemerkki: SollatekValmistajan osanumero.: 92344000
brand-logo
Näytä kaikki Sähkön laatu tuotteet

Tekninen dokumentti

Tekniset tiedot

Merkki

Sollatek

Input Voltage

230V ac

Output Power

3680VA

Output Current

16A

Number of Outlets

1

Mounting Type

Chassis

Maximum Operating Frequency

75Hz

Maximum Temperature

+55°C

Minimum Operating Frequency

45Hz

Minimum Temperature

0°C

Voltage Protection Mode

Under and Over Voltage

Wiring Configuration

L N E

Protection Type

Over Voltage and Under Voltage

Electrical Phase

1

Standards Met

ISO9001:2008

Alkuperämaa

China

Tuotetiedot

Sollatek Refrigeration Control

The FreoGuard protect equipment by disconnecting the mains supply when it goes either below or above pre-set acceptable limits. It also has an Intelligent time delay* providing added protection against frequent stops and starts

Transient Voltage Suppressors (Mains, Domestic)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. For protecting mains power systems, categories A, B and C (mains) devices are used. All mains style products in this section are location category B and exceed the requirements of location category A making them suitable for use in both locations.

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

€ 15,40

kpl (ilman ALV)

€ 19,10

kpl (Sis ALV:n)

Sollatek Refrigeration control 16A Over Voltage and Under Voltage, 3680VA, Chassis

€ 15,40

kpl (ilman ALV)

€ 19,10

kpl (Sis ALV:n)

Sollatek Refrigeration control 16A Over Voltage and Under Voltage, 3680VA, Chassis
Varastotiedot eivät ole tilapäisesti saatavilla.

Osta irtotavarana

MääräYksikköhinta
1 - 24€ 15,40
25 - 49€ 15,00
50 - 99€ 14,50
100 - 199€ 13,00
200+€ 11,70

Tekninen dokumentti

Tekniset tiedot

Merkki

Sollatek

Input Voltage

230V ac

Output Power

3680VA

Output Current

16A

Number of Outlets

1

Mounting Type

Chassis

Maximum Operating Frequency

75Hz

Maximum Temperature

+55°C

Minimum Operating Frequency

45Hz

Minimum Temperature

0°C

Voltage Protection Mode

Under and Over Voltage

Wiring Configuration

L N E

Protection Type

Over Voltage and Under Voltage

Electrical Phase

1

Standards Met

ISO9001:2008

Alkuperämaa

China

Tuotetiedot

Sollatek Refrigeration Control

The FreoGuard protect equipment by disconnecting the mains supply when it goes either below or above pre-set acceptable limits. It also has an Intelligent time delay* providing added protection against frequent stops and starts

Transient Voltage Suppressors (Mains, Domestic)

Voltage surges, often referred to as spikes or transient overvoltages are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. For protecting mains power systems, categories A, B and C (mains) devices are used. All mains style products in this section are location category B and exceed the requirements of location category A making them suitable for use in both locations.