WJ Furse, D Lightning / Surge Arrester 280 V Maximum Voltage Rating 0.01kA Maximum Surge Current Mains Protector

RS tilauskoodi: 847-2692Tuotemerkki: WJ FurseValmistajan osanumero.: 7TCA085460R0323 ESP 240D-10A
brand-logo

Tekninen dokumentti

Tekniset tiedot

Merkki

WJ Furse

Suppressor Type

Mains Protector

Maximum Voltage Rating

280 V

Mounting Type

DIN Rail

Maximum Surge Current

0.01kA

Series

D

Length

36mm

Depth

75mm

Height

90mm

Dimensions

36 x 75 x 90mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+80°C

Alkuperämaa

United Kingdom

Tuotetiedot

WJ Furse Power distribution systems enhanced surge protector - ESP-D/ DS Series

The D/ DS range offers a further enhanced series to the existing ESP range of mains protector range for specific systems, complementing the existing D1 Series.
Having a low let through voltage combined with the mains test Type 1, 2 and 3 to BS EN 61643, the D/ DS series is designed for use on low current single phase systems (up to 10A or 32A) to protect against transient over voltages on the mains supply, and offering an increased exposure level covering lighting protection zones (LPZ) 0 -3.
It also features a 3 way visual indication of protector status and advanced pre-failure warning, and remote indication facilities to a BMS via a volt-free contact. (DS Version)

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Varastotiedot eivät ole tilapäisesti saatavilla.

Tarkista myöhemmin uudelleen.

Varastotiedot eivät ole tilapäisesti saatavilla.

€ 278,00

kpl (ilman ALV)

€ 344,72

kpl (Sis ALV:n)

WJ Furse, D Lightning / Surge Arrester 280 V Maximum Voltage Rating 0.01kA Maximum Surge Current Mains Protector

€ 278,00

kpl (ilman ALV)

€ 344,72

kpl (Sis ALV:n)

WJ Furse, D Lightning / Surge Arrester 280 V Maximum Voltage Rating 0.01kA Maximum Surge Current Mains Protector
Varastotiedot eivät ole tilapäisesti saatavilla.

Osta irtotavarana

MääräYksikköhinta
1 - 4€ 278,00
5 - 9€ 266,00
10 - 19€ 253,00
20+€ 230,00

Tekninen dokumentti

Tekniset tiedot

Merkki

WJ Furse

Suppressor Type

Mains Protector

Maximum Voltage Rating

280 V

Mounting Type

DIN Rail

Maximum Surge Current

0.01kA

Series

D

Length

36mm

Depth

75mm

Height

90mm

Dimensions

36 x 75 x 90mm

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

+80°C

Alkuperämaa

United Kingdom

Tuotetiedot

WJ Furse Power distribution systems enhanced surge protector - ESP-D/ DS Series

The D/ DS range offers a further enhanced series to the existing ESP range of mains protector range for specific systems, complementing the existing D1 Series.
Having a low let through voltage combined with the mains test Type 1, 2 and 3 to BS EN 61643, the D/ DS series is designed for use on low current single phase systems (up to 10A or 32A) to protect against transient over voltages on the mains supply, and offering an increased exposure level covering lighting protection zones (LPZ) 0 -3.
It also features a 3 way visual indication of protector status and advanced pre-failure warning, and remote indication facilities to a BMS via a volt-free contact. (DS Version)

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.