Phoenix Contact 1 Phase Surge Protector, 2kV, DIN Rail Mount
Tekninen dokumentti
Tekniset tiedot
Merkki
Phoenix ContactDevice Type
Surge Protector
Voltage Protection Rating
2kV
Series
FLT-SEC-P-T1-1S-350/25-FM
Electrical Phase
1
Mounting Style
DIN Rail
Impulse Discharge Current
100kA
Length
95.2mm
Width
71.2mm
Depth
74.5mm
Dimensions
95.2 x 71.2 x 74.5mm
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+80°C
Operating Temperature Range
-40 → +80 °C
Alkuperämaa
Germany
Tuotetiedot
Phoenix Contact SEC Lightning Arresters, DIN Rail
The SEC (Safe Energy Control) range from Phoenix Contact are type 1/2, DIN rail lightning current arresters. These arresters are designed to assist with protecting your circuits by capturing any high voltages from lightning. The FLT-SEC range is in accordance with Type1/Class I and works with 1-phase power supply networks with separate N and PE (L1, PE, N). Not to mention, these lightning surge arresters can withstand high continuous voltage of 350 V AC for 230/400 V AC networks with high voltage fluctuations.
The units are designed to be mounted onto a DIN rail and provide a proofing surge protection for all your electrical device and equipment.
Industrial Circuit Protection
Varastotiedot eivät ole tilapäisesti saatavilla.
Tarkista myöhemmin uudelleen.
€ 615,00
kpl (ilman ALV)
€ 771,82
kpl (Sis ALV:n)
1
€ 615,00
kpl (ilman ALV)
€ 771,82
kpl (Sis ALV:n)
1
Tekninen dokumentti
Tekniset tiedot
Merkki
Phoenix ContactDevice Type
Surge Protector
Voltage Protection Rating
2kV
Series
FLT-SEC-P-T1-1S-350/25-FM
Electrical Phase
1
Mounting Style
DIN Rail
Impulse Discharge Current
100kA
Length
95.2mm
Width
71.2mm
Depth
74.5mm
Dimensions
95.2 x 71.2 x 74.5mm
Minimum Operating Temperature
-40°C
Maximum Operating Temperature
+80°C
Operating Temperature Range
-40 → +80 °C
Alkuperämaa
Germany
Tuotetiedot
Phoenix Contact SEC Lightning Arresters, DIN Rail
The SEC (Safe Energy Control) range from Phoenix Contact are type 1/2, DIN rail lightning current arresters. These arresters are designed to assist with protecting your circuits by capturing any high voltages from lightning. The FLT-SEC range is in accordance with Type1/Class I and works with 1-phase power supply networks with separate N and PE (L1, PE, N). Not to mention, these lightning surge arresters can withstand high continuous voltage of 350 V AC for 230/400 V AC networks with high voltage fluctuations.
The units are designed to be mounted onto a DIN rail and provide a proofing surge protection for all your electrical device and equipment.