Tekninen dokumentti
Tekniset tiedot
Merkki
Royce Thompson ElectricController Type
Detector
Sensor Type
Cadmium Sulfide
Voltage Rating
230 V
Mount Type
Wall
Wattage
600 mW
Alkuperämaa
United Kingdom
Tuotetiedot
Electronic Control Kit (CdS Cell)
CdS Photocell operated dusk-till-dawn lighting controller
Supplied with
NEMA rotaloc socket, wall mounting bracket, gaskets and fixings
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.
Varastotiedot eivät ole tilapäisesti saatavilla.
Tarkista myöhemmin uudelleen.
€ 58,00
kpl (ilman ALV)
€ 72,79
kpl (Sis ALV:n)
1
€ 58,00
kpl (ilman ALV)
€ 72,79
kpl (Sis ALV:n)
1
Tekninen dokumentti
Tekniset tiedot
Merkki
Royce Thompson ElectricController Type
Detector
Sensor Type
Cadmium Sulfide
Voltage Rating
230 V
Mount Type
Wall
Wattage
600 mW
Alkuperämaa
United Kingdom
Tuotetiedot
Electronic Control Kit (CdS Cell)
CdS Photocell operated dusk-till-dawn lighting controller
Supplied with
NEMA rotaloc socket, wall mounting bracket, gaskets and fixings
Daylight Lighting Controllers
These controllers automatically turn lights 'ON' and 'OFF' in response to changes in ambient light levels, primarily the transition from day to night and vice-versa. The more advanced types (see note below) have inbuilt logic to minimise false triggering, whereas the remainder have inbuilt time delays or higher 'OFF' thresholds, to prevent on/off cycling. As a general rule, these controllers should be sited such that they are not illuminated, by the light they are controlling. Nominal supply voltage is 230Vac.,Note regarding energy-saving negative-hysteresis controllers,Where figures for the 'OFF' threshold are lower than for the 'ON' threshold, the sensor is designed such that four thresholds are actually monitored. These are: dusk, the middle of the night, dawn and the middle of the day. Monitoring at times other than dusk and dawn enables the sensor to determine what it should be looking for next, minimising false triggering and improving overall controller operation.