Tekninen Dokumentti
Tekniset tiedot
Merkki
RS ProProduct Type
Timer Relay
Mount Type
DIN Rail, Surface Mount
Time Range
0.1 s to 100 h
Number of Contacts
2
Number of Timer Functions
1
Contact Configuration
SPDT
IP Rating
IP20
Supply DC Voltage
24 to 230 V ac
Supply AC Voltage
230, 24V ac
Mode
Star-Delta
Terminal Type
Screw
Standards/Approvals
RoHS, CE
Width
17.5mm
Alkuperämaa
United Kingdom
Tuotetiedot
RS PRO is proud to introduce the superb Star/Delta Start timer. This device is used in conjunction with external contactors and limits the duration a 3-phase motor runs in Star configuration before switching over to Delta. When power is applied, the output relay remains de-energised for the set time delay period. After the delay has elapsed, the contacts break for the set Dwell time, then change over to the energised state.
RS PRO offer a wide selection of Time Relays. Browse our range using the improved filters to locate the ideal solution for your application.
<ul><li>CE, RoHS and C-tick compliant CUL Listed</li>
<li>Conforms to IEC 61812. </li>
<li>EMC: Immunity EN 61000-6-2 (EN 61000-4-3 10V/m 80MHz - 2.7GHz) </li>
<li>Emissions: EN 61000-6-4</li></ul>
Varastotiedot eivät ole tilapäisesti saatavilla.
€ 73,50
€ 73,50 kpl (ilman ALV)
€ 92,24
€ 92,24 kpl (Sis ALV:n)
1
€ 73,50
€ 73,50 kpl (ilman ALV)
€ 92,24
€ 92,24 kpl (Sis ALV:n)
Varastotiedot eivät ole tilapäisesti saatavilla.
1
| Määrä | Yksikköhinta |
|---|---|
| 1 - 4 | € 73,50 |
| 5 - 9 | € 70,50 |
| 10+ | € 67,50 |
Tekninen Dokumentti
Tekniset tiedot
Merkki
RS ProProduct Type
Timer Relay
Mount Type
DIN Rail, Surface Mount
Time Range
0.1 s to 100 h
Number of Contacts
2
Number of Timer Functions
1
Contact Configuration
SPDT
IP Rating
IP20
Supply DC Voltage
24 to 230 V ac
Supply AC Voltage
230, 24V ac
Mode
Star-Delta
Terminal Type
Screw
Standards/Approvals
RoHS, CE
Width
17.5mm
Alkuperämaa
United Kingdom
Tuotetiedot
RS PRO is proud to introduce the superb Star/Delta Start timer. This device is used in conjunction with external contactors and limits the duration a 3-phase motor runs in Star configuration before switching over to Delta. When power is applied, the output relay remains de-energised for the set time delay period. After the delay has elapsed, the contacts break for the set Dwell time, then change over to the energised state.
RS PRO offer a wide selection of Time Relays. Browse our range using the improved filters to locate the ideal solution for your application.
<ul><li>CE, RoHS and C-tick compliant CUL Listed</li>
<li>Conforms to IEC 61812. </li>
<li>EMC: Immunity EN 61000-6-2 (EN 61000-4-3 10V/m 80MHz - 2.7GHz) </li>